Calculators and estimators

Work out rough figures before you ask for a quote: solar output and savings, aircon size, evaporative cooler airflow and cable voltage drop. Each calculator has a button that sends your figures to us with the quote request, so we can quote faster.

Solar

Solar savings estimator

This is an estimate only, not a quotation or a guarantee. All figures are editable. Change them to match your own electricity bill and site. Not sure how much sun your town gets? Check our solar map.

Your assumptions

Enter the size you are considering. There is no default — a typical house might be 3–8 kWp, but yours may differ.
Starting value 6.25, from Upington GHI 2 282 kWh/m²/year ÷ 365. Source: CRSES / GeoModel Solar Upington report. Other towns differ: see average summer, winter and annual sun hours for 33 towns on our solar map.
Starting value R3.44/kWh (343.61 c/kWh), Eskom Homelight 60A non-local authority, VAT-inclusive energy charge, 1 April 2026–31 March 2027. Source: Eskom Tariffs and Charges Booklet 2026/27. Upington may be billed on a Dawid Kruiper municipal tariff — enter the rate from your bill.
A planning assumption you can change, not a measured figure for your roof. A common planning range is 0.75–0.85 (inverter, heat, soiling and wiring losses). It is not a VRAUTECH guarantee.
Tells us which way you are leaning. We will still recommend what suits your site.

Estimated output and saving

Formula: daily kWh ≈ kWp × peak sun hours × performance ratio. Monthly uses 30.44 days; annual uses 365 days. Saving assumes all of that energy replaces grid purchases at your tariff, with no export, fixed charges or degradation.

Per day—
Per month—
Per year—
Est. annual saving—

Estimate only. It does not include system cost, financing, municipal export rules, load-shedding, shading, panel degradation or fixed daily charges. Ask VRAUTECH for a site-specific quote.

HVAC · Air conditioning

Aircon size calculator (BTU)

Our quick rule of thumb: length (m) × breadth (m) × 750 = BTU/h. We then round up to the next standard split-unit size.

Your room

Ranges listed are those the brands or their South African retailers list. Where a range's sizes are published, only ranges offered in your size are shown. Availability changes; we will confirm the exact model when we quote.

Suggested size

Floor area—
L × B × 750—
Standard unit size—
Load in kW (÷ 3 412)—

Rule of thumb only. Rooms facing west or north, with lots of glass, a high or uninsulated ceiling, or many people or appliances may need a bigger unit. We confirm the size on site before we quote. Standard sizes used: 9 000, 12 000, 18 000, 24 000, 30 000, 36 000, 48 000 and 60 000 BTU/h.

HVAC · Evaporative cooling

Evaporative cooler sizer

Evaporative coolers are sized by airflow, not BTU. Airflow needed = room volume (m³) × air changes per hour. Evaporative cooling works best in hot, dry air like ours, and the space needs open windows or vents so the air can leave.

Your space

AIRAH guidance: a space cooled by an evaporative cooler should typically get at least 20 and at most about 40 air changes per hour. The ceiling height starts at 2.7 m; change it to yours.

Airflow needed

Room volume—
Air changes—
Airflow (m³/h)—
Airflow (L/s)—

Choose a cooler whose rated airflow is at least this figure. We match it to a specific model when we quote.

Method: AIRAH HVAC&R Skills Workshop, module 48: “Residential evaporative air cooling systems” (air change rate 20–40 per hour; airflow = ACH × volume). The same volume × air-changes method is used by the US DOE Building America Solution Center.

Electrical · Cable sizing

Voltage drop calculator

See how cable size, distance and installation method affect voltage drop. SANS 10142-1 limits the drop from the supply point to any outlet to 5 %: 11.5 V on a 230 V single-phase circuit, or 20 V on a 400 V three-phase circuit.

Your circuit

230 V single-phase, 400 V three-phase (line to line).
Distance along the cable route from the DB or supply point to the load. The return path is already in the table values.

Cable ratings are for 30 °C air or 25 °C soil. Hotter surroundings lower the safe current.

Voltage drop and current check

Design current—
Table value—
Voltage drop—
Drop as %—
Max run at 5 %—
Derated cable rating—
Smallest size that passes both checks—

Enter the load and distance to check the 5 % limit.

Enter the load to check the current rating.

Estimate only. Formula: voltage drop (V) = mV/A/m × current (A) × length (m) ÷ 1 000. It does not include grouping with other cables, the drop already on the supply side, motor starting current, earth-fault loop impedance or protection settings. The final cable size and design must be done and certified by a registered electrician. VRAUTECH will check this on site.